ALTAIR HYPERFORM TUTORIAL PDF

Assessing formability. 4. Optimization of blank size. 5. Mapping of forming results. 6. Conclusion. One step forming simulation with HyperForm. Due to space limitations only a sample tutorial based on HyperForm is presented below. . then Altair HyperWorks then HyperMesh. A User Profiles window. manual named Altair HyperForm, 1-Step Stamping Analysis as it .. For this tutorial, please ensure the die tool component is setup with a fully.

Author: Mazukree Febei
Country: Romania
Language: English (Spanish)
Genre: History
Published (Last): 11 December 2013
Pages: 410
PDF File Size: 9.79 Mb
ePub File Size: 7.56 Mb
ISBN: 768-3-43542-119-9
Downloads: 89823
Price: Free* [*Free Regsitration Required]
Uploader: Gojind

With 15 years of experience in tooling design, Weiner and his Toronto-based practice offered a service that no one else had perfected but that was crucial to a key process in automotive manufacturing: To fulfill the requirements for crash and modal analysis, the company used OptiStruct to optimize the component, RADIOSS and other external solver to run the calculations and HyperView for the post processing.

Resource Library

Hence, numerical simulation could be a viable approach to predict material behavior during composite forming.

In doing so, Supreme was able to optimize the blank as well as minimize die tryouts. Define new process that includes accurate component data Altair Solution: Download the HyperForm Brochure Share: View the Video Share: Another topic to be discussed is the forming hyperfor of a composite rib and result mapping.

Carrier Nesting Carrier option added to support nesting for progressive die use cases. Hence, a study on crash simulations is performed, after mapping fibers angles from stamping simulation. The two main interests vs.

Subscribe to join our Newsletter Learn about product training, news, events and more. A modeling approach was developed and applied that allowed for rapid change of a baseline human body model into geometries representing adults with different BMIs without the need for re-meshing the models.

  MACIEJ MATASEK ENGLISH ADVANCED VOCABULARY AND STRUCTURE PRACTICE PDF

HyperForm Brochure Altair HyperForm is an industry proven comprehensive finite-element-based sheet metal forming simulation framework. HyperForm delivers a cost-effective solution to meet the demands of customers varying from individual analysts, and tool shops, and to large OEMS. Leveraging numerical analysis, Godrej was also able to predict the size, shape and location of the blank accurately.

Solid Hex Meshing the Human Lumbar Spine Computational modeling and simulation, which uses computer-based mathematical techniques, is on the verge of revolutionizing the field of medical devices.

Tutorial file for hyperform – Altair HyperForm – Altair Forum

It was important for PWO to have a software suite yyperform that hyperfrm cover all simulation tasks within one graphical user interface and licensing system. The compared result is the shear angle after stamping that is, the final angle between warp and weft fibers, at several prescribed points on the ply.

Speeding Development Time While Cutting Prototype Costs Wagon Automotive, a system and module supplier of components to major car builders, sought ways to accelerate product development and reduce prototyping costs while maintaining high quality. Enhanced Formability through Hydroforming Cut sheet metal forming time and costs through simulation-based techniques. Enhanced Formability through Hydroforming Learn More. Forming Simulation hypegform Woven Composite Fibers and Its Influence on Crash Performance The automotive industry, in its constant quest for weight reduction, is increasingly considering composite materials as a substitute for sheet metal components to meet future fuel consumption standards.

Altair HyperWorks Training – Online Learning, Tutorials, Videos and Course Schedule

However, composite forming processes are expensive and difficult to control because of the complexity of the material behavior with fiber and matrix layers or plies and its dependency on many parameters, such as non-linearity of tensile stiffness, effect of shear rate, temperature and friction. Modeling techniques allow computer models to eliminate bad ideas and refine the good ones long before they leave the drawing board.

  BTA08 400B PDF

HyperWorks at Wagon Automotive: Carrier Nesting Learn More. Thermoplastic composites TPC developed by Solvay Engineering plastics are composites based on polyamide 6 or 6.

Its unique process-oriented environment captures the forming process with a suite of highly tailored and configurable analysis and simulation tools to optimize all aspects of stamped products development.

HyperForm Brochure Learn More. PWO received the CAD model, the design space definition and other pre-defined standards of the component from the customer and developed and produced the fitting cross beam based on this information. Mark Auto re-designed two existing dies for wheel arch an wheel housing and was able to dramatically reduce material scrap with minimum rework in their tools while not compromising on component quality.

Bird Strike and Other Nonlinear Transient Analyses This webinar covers bird strike analysis on a wing, starting out with model setup, going over the impactor management and ending in tutorila analysis of the results. He carries out metal-forming simulations for major tooling suppliers and originalequipment manufacturers. HyperForm was used to check the production feasibility of the individual components and for metal forming simulation tasks.

Biomedical and Life Sciences. Wagon Automotive now uses HyperWorks during the entire development cycle, from concept design to optimization. Added carrier options includes double side carrier, double side central carrier,and double side nested carrier. View on Demand Share: The Draw Shell was simulated using HyperForm to evaluate different tooling options.

The variation of this angle has a strong impact on material characteristics which severely deteriorates when a critical value is reached.